Important: Our new home for AFM probes is launching. The US and Canada is now served at estore.oxinst.us . Australia, India, Singapore, South Korea, and Taiwan are served at estore.oxinst.com . You must create a MyOI account to use the store, instructions here . If you have any questions or concerns please contact: Dominic.Paszkeicz@oxinst.com
0item(s)

カートには何もはいっていません。

Product was successfully added to your shopping cart.

Probes

Set Ascending Direction

   

Items 1 to 50 of 100 total

  1. 1
  2. 2
  1. AC200TS

    Silicon probe with visible apex tip for force modulation or soft tapping on medium to hard samples.
    f = 150 kHz   |   k =9 N/m   |   tip coating: none

    Starting at: ¥45,000

  2. ASYELEC.01-R2

    Asylum electrolever with visible tip apex and conductive coating for nano-electrical measurements
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Ti/Ir

    Starting at: ¥46,000

  3. BL-AC40TS

    BioLever Mini; small nitride cantilever with silicon tip for tapping mode in liquid.
    f = 110 kHz   |   k = 0.09 N/m   |   tip coating: none

    Starting at: ¥50,000

  4. AC160TS-R3

    Also known as OTESPA; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: ¥45,000

  5. AC240TS-R3

    Also known as OLTESPA; medium soft cantilever for topgraphy and viscoelasticity of soft samples.
    f = 70 kHz   |   k = 2 N/m   |   tip coating: none

    Starting at: ¥45,000

  6. AC10DS

    BioLever fast (also known as BL-AC10DS); ultra small cantilever for tapping mode in liquid.
    Only on AFMs with small laser spot such as Cypher.
    f = 1500 kHz   |   k = 0.1 N/m   |   tip coating: none

    Starting at: ¥49,000

  7. AC240TSA-R3

    OLTESPA with Au reflective coating; medium soft cantilever for topography and viscoelasticity of soft samples.
    f = 70 kHz   |   k = 2 N/m   |   tip coating: none

    Starting at: ¥50,000

    In Stock

  8. ASYELEC.02

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 300 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: ¥40,000

  9. ASYMFM-R2

    Silicon probe with visible tip apex and magnetic coating for standard MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoCr

    Starting at: ¥45,000

  10. AC160TSA-R3

    OTESPA with Au reflective coating; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: ¥50,000

  11. ASYMFMLM-R2

    Silicon probe with visible tip apex and magnetic coating for low moment MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoCr

    Starting at: ¥51,000

  12. AC10FS

    BioLever fast with CNF tips (also known as BL-AC10FS); Carbon Nano Fiber probe for high resolution imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1500 kHz   |   k = 0.1 N/m   |   tip coating: none

    Starting at: ¥216,000

  13. Arrow UHFAuD

    Silicon probe with visible tip apex and Au reflex coating for high speed imaging.
    f = 2000 kHz   |   tip coating: none

    Starting at: ¥91,000

  14. AC240TM-R3

    Also known as OSCM; conductive probe with visible apex tip for electrical measurement.
    f = 70 kHz   |   k = 2 N/m   |   tip coating: Ti/Pt

    Starting at: ¥52,000

  15. ASYMFMHC-R2

    Silicon probe with visible tip apex and magnetic coating for high coercivity MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoPt/FePt

    Starting at: ¥60,000

  16. ASYMFMHM-R2

    Silicon probe with visible tip apex and magnetic coating for high moment MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoCr

    Starting at: ¥51,000

  17. AC55TS

    Fast silicon probe with visible apex tip for fast imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1600 kHz   |   k = 85 N/m   |   tip coating: none

    Starting at: ¥38,000

  18. ASYELEC.02-R2

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: ¥46,000

  19. PtSi-FM

    Sharp conductive probe with PtSi coating for electrical measurements.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: PtSi

    Starting at: ¥223,000

  20. ASYMFMLC-R2

    Silicon probe with visible tip apex and magnetic coating for low coercivity MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: permalloy

    Starting at: ¥51,000

  21. FMR

    Silicon probe with Al reflex coating for force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: ¥43,000

  22. ASYMFMSMPL

    Five each of Asylum MFM levers (ASYMFM; ASYMFMHC-R2; ASYMFMHM; ASYMFMLC; ASYMFMLM); Veeco equiv - MESPSP

    Starting at: ¥211,000

  23. PPP-EFM

    Conductive probe for electrical measurements in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: ¥68,000

  24. NCSTR

    Silicon probe with Al reflex coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: ¥43,000

  25. SSS-FMR

    Silicon probe with sharp tip for high resolution imaging in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: ¥114,000

  26. EFM

    Silicon probe with PtIr coating for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: ¥58,000

  27. PPP-NCHAuD

    Silicon probe with Au reflex coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: ¥49,000

  28. PPP-NCSTR

    Silicon probe with Al reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: ¥49,000

  29. PPP-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: ¥105,000

  30. NCHPt

    Silicon probe with PtIr coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: ¥58,000

  31. NCHR

    Silicon probe with Al reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: ¥43,000

  32. SC-35-M

    CoNi side-coated tip silicon probe for high hi-resolution MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoNi

    Starting at: ¥109,000

  33. CDT-NCHR

    Silicon probe with conductive diamond coated tip for electrical measurements.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: ¥223,000

  34. PPP-LC-MFMR

    Silicon probe coated with low coercivity material for MFM on soft magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: ¥105,000

  35. CONTR

    Silicon probe with Al reflex coating for contact mode.
    f = 13 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: ¥43,000

  36. PPP-NCHAu

    Conductive silicon probe with Au tip coating for electrical measurements in non-contact/tapping mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: Au

    Starting at: ¥59,000

  37. USC-F0.3-k0.3

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 300 kHz   |   k = 0.3 N/m   |   tip coating: none

    Starting at: ¥134,000

  38. PPP-CONTSCAuD

    Silicon probe with short cantilever and Au reflective coating for contact mode.
    f = 23 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: ¥49,000

  39. AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: ¥201,000

  40. PPP-NCSTAuD

    Silicon probe with Au reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: ¥49,000

  41. PPP-NCLAuD

    Silicon probe with long cantilevr and Au reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: ¥49,000

  42. PPP-LM-MFMR

    Silicon probe coated with low moment material for MFM on magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: ¥105,000

  43. USC-F5-k30

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 5000 kHz   |   k = 30 N/m   |   tip coating: none

    Starting at: ¥134,000

  44. PPP-CONTAuD

    Silicon probe with Au reflective coating for contact mode.
    f = 15 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: ¥49,000

  45. AR10-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: ¥201,000

  46. PPP-FMAuD

    Silicon probe with Au reflective coating for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: ¥49,000

  47. Arrow FMR

    Silicon probe with tip at the end of cantilever and Al reflex coating for force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: ¥41,000

  48. CONTSCR

    Silicon probe with short cantilever for contact mode.
    f = 23 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: ¥43,000

  49. SC-20-M

    CoNi side-coated tip silicon probe for high hi-resolution MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoNi

    Starting at: ¥129,000

  50. ATEC-EFM

    Conductive probe with visible tip apex for electrical measurements in modulation mode.
    f = 85 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: ¥134,000

Set Ascending Direction

   

Items 1 to 50 of 100 total

  1. 1
  2. 2